Publication: Development and validation of an Automated scoring system for trunk Impairment scale 2.0.
No Thumbnail Available
Date
2025-02
Authors
Tay, Jia Yi
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The Trunk Impairment Scale Version 2 (TIS 2.0) is a validated clinical assessment tool used to assess motor impairment in the trunk after a stroke. TIS 2.0 consists of two subscales which are dynamic sitting balance (DSB) and coordination (COO) subscale. Traditionally, the assessments rely heavily on the ability of physiotherapists in detecting minor changes in motion and observing limb movements. These can be time consuming and reduce their availability for rehabilitation work. An automated scoring system for TIS 2.0 was proposed to provide a more reproducible and standardized alternative to manual physiotherapist assessments. A total of eight existing studies had ventured into the realm of automation for trunk performance assessments. These studies developed automated systems based on existing clinical assessment tools and validated their findings on populations including elderly, healthy
individuals and those with brain-related conditions. Researchers employed diverse methods such as inertial sensory systems, image processing, and mechanical measurement systems to collect data. However, none of these studies specifically targeted TIS 2.0, nor validate their systems using data from stroke patients. Moreover, the previous studies apply the classification methods are lack of transparency and interpretability. Decisions were not tied to predefined clinical criteria and less straightforward. This study bridges these gaps and focuses on developing an automated scoring system for TIS 2.0 based on data gathered from the video-based motion capture system and employing a rule-based classification algorithm. In the development phase, motion data from lay actors simulating stroke condition were collected using OpenCap. This data was utilized to create metrics and establish cut-off values for a rule-based classification. The spatiotemporal features were developed based on the manual scoring guidelines. The discriminant abilities of the metrics were evaluated
using the area under the curve (AUC). The discriminant abilities of the features used in the DSB subscale are considered excellent to outstanding (AUC ≥ 0.717), and the COO subscale ranged from poor to outstanding (AUC ≥ 0.667). In the testing phase, the performance of the developed system was assessed on 19 stroke patients using both automated system and manual scoring by nine physiotherapists. The automated scores aligned with physiotherapists’ scores, achieving an average percentage of agreement 71.1%. The total TIS 2.0 scores generated by the automated method showed moderate correlation with the sum of mode-determined task scores (R = 0.526, p < 0.05). These findings suggest that the proposed automated system demonstrates comparable validity to assessments by physiotherapists.