Publication: Fatigue analysis of a piezoelectric Energy harvester for an electric Vehicle driving motor system.
| datacite.subject.fos | oecd::Engineering and technology::Mechanical engineering | |
| dc.contributor.author | Yang, Ping | |
| dc.date.accessioned | 2026-11-12T07:59:25Z | |
| dc.date.available | 2026-11-12T07:59:25Z | |
| dc.date.issued | 2025-07 | |
| dc.description.abstract | With the advancement of intelligent networked vehicles, the demand for sustainable energy to power distribute wireless sensors has intensified. Piezoelectric energy harvesters (PEHs) offer a promising solution by converting ambient mechanical vibrations into electrical energy. This study aims to design, optimize, and evaluate PEHs for application in the driving motor system (DMS) of electric vehicles, focusing on enhancing both electrical output and fatigue life under realistic operational conditions. Road simulation experiments are conducted to capture the vibration characteristics of the DMS. The results reveal that both low and high frequency vibration energy are abundant during vehicle operation, with dominant frequencies observed at 15 Hz and 250 Hz. Accordingly, two optimized PEH designs are proposed: a low-frequency Gauge-shaped beam (15 Hz) and a high-frequency T-shaped beam (250 Hz). Finite element analysis (FEA) shows that the fatigue life cycle of the Gauge-shape PEH beam is 1.1993 x 10⁶ with output voltage 114.11 V, and the fatigue life cycle of the T-shape beam is 1 x 109 with output voltage 29.5 V, which illustrated the Gauge-shape PEH beams exhibit excellent electromechanical characteristics, and high-frequency PEH beams also exhibit great overall performance in finite element analysis. The final optimized T-shape beam with eigenfrequency 250 Hz and Gauge-shape with eigenfrequency 15 Hz beam are fabricated for further research. The voltage outputs under cyclic operational conditions load on the test bench are also obtained. The results show that PEH can efficiently convert the high-frequency vibration energy of the motor into electrical energy, and the maximum voltage reached 144 V. In the fatigue experiment, crack of the high-frequency PEH is not observed during 2.03 x 10 cycles, and the low-frequency PEH beam underwent final failure at the middle of the piezoelectric transducer after 3.1 x 105 cycles load. Also, the relationships and intrinsic connections between the output voltage, resonance frequency, and the number of load cycles of the two PEHs are analyzed and compared. The result indicated that the output performance of the high-frequency beam is more stable, and its overall performance is better, making it complementary to the low-frequency beam. Combined with the vibration energy harvesting module and LED light test, the performance of harvesting bi-frequency vibration energy from DMS is discussed. The outcome of this study could provide a reference for improving the structuralfatigue and electrical output of PEH. | |
| dc.identifier.uri | https://erepo.usm.my/handle/123456789/25433 | |
| dc.language.iso | en | |
| dc.title | Fatigue analysis of a piezoelectric Energy harvester for an electric Vehicle driving motor system. | |
| dc.type | Resource Types::text::thesis::doctoral thesis | |
| dspace.entity.type | Publication | |
| oairecerif.author.affiliation | Universiti Sains Malaysia |