Publication:
An improved control strategy for single-phase inverter with active and reactive power control for grid connected photovoltaic systems.

Loading...
Thumbnail Image
Date
2025-06
Authors
Mohamed Yusof, Nur Fairuz
Journal Title
Journal ISSN
Volume Title
Publisher
Research Projects
Organizational Units
Journal Issue
Abstract
Control strategies for the grid-connected inverters have become a central focus as photovoltaic (PV) grid-connected systems continue to proliferate. The inverters must be capable of seamlessly transferring power to the grid while supporting the required load. They face multiple challenges related to synchronization, power quality, and control efficiency, particularly under fluctuating irradiance and grid disturbances. Conventional synchronization methods such as Phase-Locked Loop (PLL) and control strategies like PI controller, exhibit limitations in maintaining unity power factor and mitigating harmonic distortion, especially in weak or unbalanced grid conditions. Additionally, the intermittent nature of solar energy and the constraints of traditional Maximum Power Point Tracking (MPPT) algorithms necessitate the development of advanced, low-complexity control strategies that ensure compliance with IEEE standards while enhancing system reliability and real-time performance. This thesis presents an enhanced control strategy for a single-phase grid-connected inverter that facilitates bidirectional operation between the inverter, load, and utility grid while sustaining unity power factor and maintaining Total Harmonic Distortion (THD) within the 5% limit as stipulated by IEEE Standard 1547-2018 and IEEE 519-2014. The proposed control algorithm utilizes a variable step-size incremental conductance (VS-InCond) method as the MPPT algorithm, ensuring optimal energy extraction from the PV array under varying environmental conditions, such as fluctuations in solar irradiance and temperature. This approach improves overall system efficiency by dynamically adjusting the PV system's operating point to its maximum power output. The VS-InCond method is integrated with Double-Band Hysteresis Current Control (DBHCC) and employs a modified PQ theory for grid synchronization. DBHCC strategy has been developed to generate a reference current based on the decomposition of the single-phase load current, enabling the controller to maintain a set power point during load variations. The primary objective is to achieve seamless control of power flow from the solar PV to the inverter and from the inverter to the load, while also enabling bidirectional power flow to and from the utility grid, without relying on a PLL. The proposed strategy was evaluated through simulation and experimental testing under four operating modes defined by solar irradiance levels ranging from 1000 W/m² to 350 W/m² at a constant temperature of 25 °C. The performance metrics assessed include active and reactive power control, THDs for voltage and current, power conversion efficiency, and dynamic response under load and irradiance variations. Additionally, a laboratory prototype was developed, and a Digital Signal Processor (DSP) TMS320F28379D was used to validate the effectiveness of the proposed algorithms. Further comparative evaluation on the model was conducted using a Proportional-Resonant (PR) controller. Both simulation and experimental results demonstrated that the proposed PQ-DBHCC algorithm outperforms the PR controller. Power conversion efficiency ranged from 93 % to 98 %. In terms of THD analysis for current and voltage, they are lower than 5 % maximum limit recommended by IEEE 519-2014 standard across four operating modes. In resistive load conditions, simulated THD values for voltage and current ranged from 0.802 % to 1.025 %, while experimental THD increased to 2.5 % until 4.6 % for voltage, and 2.5 % – 4.8 % for current. Under inductive loading, simulated THDs ranged from 0.502 % to 0.86 % (voltage) and 0.59 % to 1.08 % (current), while experimental values ranged from 1.6 % to 2.7 % (voltage) and 2.5 % to 4.9 % (current), reflecting higher harmonic content at lower irradiance levels. Additionally, grid power factor remained consistently close to unity across all test scenarios, with values ranging from 0.99 to 1 under resistive load, and exceeding 0.978 under inductive load, demonstrating the robustness of the proposed system in maintaining compliance with IEEE standards under diverse operating conditions. The results confirm that the proposed control strategy not only ensures compliance with IEEE standards for power quality and grid interconnection but also enhances system resilience and efficiency under varying environmental and loading conditions, with the potential to improve the reliability and stability of distributed in smart grids.
Description
Keywords
Citation