Publication:
Simultaneous electrochemical sensing of lead and cadmium heavy metal ions using composite polymer modified screen printed electrode.

No Thumbnail Available
Date
2025-01
Authors
Ong, Chyh Shyang
Journal Title
Journal ISSN
Volume Title
Publisher
Research Projects
Organizational Units
Journal Issue
Abstract
In response to escalating heavy metal pollution, electrochemical method presents a promising technology for metal ions detection. Screen-printed electrode (SPE) has garnered significant attention, though its sensitivity to trace metal ions remains a challenge. This is primarily due to the lack of selectivity for target ions and hindered surface conductivity caused by polymer binder employed in printing process. This study involved strategic modification of the SPE surface with metal-attracting polymers, including cellulose acetate (CA), chitosan (Cts), nafion-117 (Naf), and nylon-6 (Nyl). The modified SPEs’ sensing performance in detecting lead(II) (Pb2+) ions, was conducted through square wave anodic stripping voltammetry (SWASV), incorporating a comprehensive analysis of morphological and electrochemical perspectives. Additionally, polymer concentration (1 – 5 wt.%) were examined to understand their impact on metal ions detection. Results indicated that Naf/SPE exhibited improved sensitivity from 33.5 to 37.4 µA/ppm with increasing polymer concentration, attributed to effective interaction between sulfonate (-SO3-) ligands and Pb2+ ions. While metal-attracting polymers are known to enhance sensor sensitivity, understanding the dominating factors that improve SPE performance remains scarce. The study further scrutinized the factors from both physical and chemical perspectives, correlating findings with sensor’s performance in detecting Pb2+ and cadmium(II) (Cd2+) ions. The presence of -SO3- ligands and the negatively charged surface of Naf/SPE are the dominating factors that improve the SPE’s sensitivity. To improve surface wettability, a polymer composite was synthesized by integrating hydrophilic poly(sodium 4-styrenesulfonate) (PSS) into the Naf polymer matrix. The composite sensor showed a 40% lower contact angle than Naf/SPE, while maintaining high selectivity towards metal ions. Cyclic voltammetry revealed an electrochemical active surface area of 0.56 cm2 for cations and 0.32 cm2 for anions. Introducing bismuth(III) (Bi3+) ions via in-situ approach further enhanced the SPE’s performance. Under optimum SWASV condition, the Naf-PSS/Bi/SPE achieved a limit of detection (LOD) of 2.55×10-3 ppm for Pb2+ (0.003 – 0.15 ppm) and 4.57×10-3 ppm for Cd2+ (0.005 – 0.4 ppm), meeting the wastewater discharge standards of both WHO (Pb2+: 0.01 ppm; Cd2+: 0.005 ppm) and Malaysia (Pb2+: 0.5 ppm; Cd2+: 0.020 ppm). Besides, the Naf PSS/Bi/SPE displayed remarkable stability (% signal drop < 15% over 7-day period), reproducibility (RSD < 2.5% based on five identical electrodes), repeatability (RSD < 5% over 10 measurements), and anti-interference capability against interfering ions including calcium(II) (Ca2+), zinc(II) (Zn2+), chromium(III) (Cr3+), and nickel(II) (Ni2+). These robust properties, coupled with ease of batch fabrication, highlight the Naf-PSS/Bi/SPE’s potential for practical heavy metal detection applications.
Description
Keywords
Citation