Publication: Investigation of the bending Performance of aged NiTi archwires in Orthodontic configurations with Different inter-bracket distances.
No Thumbnail Available
Date
2025-03
Authors
Ishak Latiffi, Nur Ainul Nurina
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Current NiTi shape memory alloy archwires used in orthodontics exhibit pseudoelastic properties, but their force transmission behavior during bending in a bracket system is
difficult to control in a progressive or intermediate manner. This limitation affects the efficiency and predictability of orthodontic treatments. One potential solution is modifying the microstructure of the NiTi wires through heat treatment, particularly ageing, to adjust their force-deflection characteristics. However, the optimal ageing conditions that achieve the desired reduction in bending force while maintaining mechanical performance across different orthodontic configurations are not well established. This study aims to investigate the effect of ageing treatment on the forcedeflection behavior of superelastic NiTi archwires in orthodontic configurations with varying inter-bracket spacing. The commercial superelastic NiTi archwires were aged to different temperatures ranging from 370 °C to 520 °C for a duration of 15 to 45 minutes. After this ageing process, their bending deformation was assessed using a standardized three-point bending test. The ageing conditions that resulted in the greatest decrease in bending force were chosen for evaluating the bending performance
in an orthodontic setup with different inter-bracket spacing ranging from 7.0 mm to 9.0 mm. The bending performance was assessed based on three force parameters: the loading force, the unloading force, and the force slope. The three-point bending test clearly demonstrates that the ageing treatment effectively decreased the initial bending force exerted by the as-received NiTi archwire. Three best-case ageing conditions were chosen from the three-point bending test due to their ability to induce lower forces during the unloading cycle. The archwires aged at 490 °C for 15 minutes, 460 °C for 30 minutes, and 490 °C for 45 minutes exhibited the greatest force reductions, reducing the initial unloading force from 2.9 N to 2.2 N, 2.2 N, and 1.7 N, respectively. The three chosen aged NiTi archwires exhibited improved unloading force when subjected to bending utilizing the three-bracket bending arrangement. After being heat treated at 460 °C for 30 minutes, the unloading force of the as-received NiTi archwire measured at 2.0 mm deflection was reduced from 4.9 N to 1.9 N in the 7.0 mm inter-bracket setting. The best ageing condition for the aged NiTi archwires was found to be 45 minutes at 490 °C, since this produced the lowest and most consistent unloading force,
from about 1.7 N to 3.5 N, independent of the variation in the inter-bracket distances.The findings from this work indicate that the ageing treatment effectively enhances the
thermal and mechanical properties of the commercial NiTi archwire, leading to improved bending behaviors across various inter-bracket settings in orthodontic treatment.