Publication: A comparative study of ac partial discharge activity due to the presence of metal particles in different liquid dielectrics of high voltage transformers.
No Thumbnail Available
Date
2025-06
Authors
Azmi, Kiasatina
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
One of the most critical components of an electrical power system is a transformer. Almost all high voltage (HV) power transformers use petroleum-based mineral oil as a cooling and insulating medium. Nevertheless, due to environmental issues and the lifecycle of mineral oil, the adoption of a renewable alternative, such as vegetable oil, emerges as the preferred solution. Currently, palm fatty acid ester (PFAE), a derivative product of palm oil, has been successfully developed and utilised as transformer oil in power transformers. However, partial discharge (PD) under the influence of metal particle contaminants in PFAE has never been reported. Therefore, the PD characteristics in PFAE, as influenced by metal particles and their dependence on different particle numbers and temperatures at varied electric field strengths and gap distances have been investigated. The PD characteristics in PFAE such as partial discharge inception voltage (PDIV), phase-resolved partial discharge (PRPD) pattern, PD magnitude, PD number, and PD frequency spectrum have been compared with those of mineral oil. The PD activity started at an electric field strength 50% higher than the minimum threshold required to produce PDIV at a 5mm gap distances has been investigated. The PDIV under the effects of particle number and temperature in PFAE was lower compared to mineral oil as the gap distance increased. The PRPD pattern due to particle number and temperature in PFAE was different compared to mineral oil. As the electric field strength increased, the shift of PDs in positive and negative half cycles to the zero-crossing point of their opposite half cycle in PFAE was faster compared to mineral oil. Meanwhile, as the gap distance increased, the shift of the PDs in positive and negative half cycles to the zero-crossing point of their respective half cycle in PFAE was slower compared to mineral oil. The PRPD pattern of mineral oil was found to follow the PRPD pattern in PFAE as the temperature increased. The mean PD magnitude in PFAE was higher compared to mineral oil, regardless of particle number and temperature. The dependence of PD number on particle number in PFAE was lower compared to mineral oil at high electric field strength. Meanwhile, the PD number in PFAE exhibited minimal changes, whereas the PD number in mineral oil demonstrated a gradual reduction as the gap distance increased. Under the influence of temperature, the PD number pattern in mineral oil was found to follow the PD number pattern in PFAE at high temperatures. The PD frequency spectrum under the effects of particle number and temperature in PFAE and mineral oil was found to have similar peaks of PD dominant frequency which were at f1 = 40MHz, f2 = 100MHz, and f4 = 586MHz, but different at f3, where f3 = 280MHz – 360MHz in PFAE, while f3 = 327MHz in mineral oil. The PD frequency spectrum of PFAE was narrower, while its PD amplitude was higher compared to mineral oil. The findings from the experiment are very useful for clarifying the viability of PFAE as a substitute for mineral oil in transformers and providing valuable information for PD detection engineers, inspectors, and designers of PFAE-filled power transformers.