The Effect Of Digital And Physical Filters On Image Quality For Quantitative Tc-99m Single Photon Emission Computed Tomography (Spect)

dc.contributor.authorA. Latiff, Rukiah
dc.date.accessioned2019-09-11T04:34:16Z
dc.date.available2019-09-11T04:34:16Z
dc.date.issued2010-05
dc.description.abstractAn absolute quantitation can be made on SPECT data to accurately measure the volume and estimate total radionuclide activity in the organ or lesion. The major problem to produce an accurate quantitation is the contamination of SPECT images by scattered photons. The aim of the study is to investigate the effect of physical filters on image quality in quantitative SPECT imaging. Two types of material filters viz copper (Cu) with 0.05 cm thickness and aluminium (Al) with 0.04 cm (aluminium A) and 0.06 cm thickness (aluminium B) were applied as scattered radiation correction method. Six different mathematical filters such as Ramp, Parzen, Hanning, Hamming, Butterworth and Gaussian filter with different order and cut-off frequency (cof) were used to reconstruct the images. The image for each phantom was acquired by using low-energy-high-resolution (LEHR) collimator, symmetrical window of 126 to 154 keV (centered at 140 keV), 64 views over 3600 and 30 seconds/projection. The radius of rotation was 30 cm from the phantom with 64 x 64 x 16 matrix. The image count difference between before and after reconstruction using Ramp (76 to 78 %), Gaussian and Butterworth filters were independent of the size of the phantoms. Parzen, Hanning and Hamming showed an image count dependency on size for small phantom sizes (10 ml, 20 ml, 30 ml and 40 ml). As cof increased the image count reduction increased. Contrast and signal-noise ratio (SNR) increased when the sizes of phantoms and cof increased for all mathematical filters. Using specific physical filter does not suit different sizes of phantom for contrasts and SNR improvement.en_US
dc.identifier.urihttp://hdl.handle.net/123456789/8854
dc.language.isoenen_US
dc.publisherUniversiti Sains Malaysiaen_US
dc.subjectDigital And Physical Filtersen_US
dc.subjectTc-99m Single Photon Emission Computed Tomography (Spect)en_US
dc.titleThe Effect Of Digital And Physical Filters On Image Quality For Quantitative Tc-99m Single Photon Emission Computed Tomography (Spect)en_US
dc.typeThesisen_US
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: